PFC HIGH PERFORMANCE
By using input power factor correction technology together with the lastest IGBT power factor components, all UPS units comply with the worldwide energy saving requirement.
RELIABILITY
By using the most advanced microprocessor to reduce the size and the number of components, greatly reduce failvre rate of the UPS. IGBT technology is used to operate the inverter at high frequency. This enhances reliability significantely.
AUTO-SENSING
Upon power on, the UPS units will start to perform a self-test on its components and the load, so as to detect problems immediately and prevent any errors.
SELF-PROTECION FEATURE
All UPS units equipped with the self-protection feature, the systems shuts itself down upon detection of overloads short circuit low battery voltage, or excessive temperature.

INTERFACES

All UPS units have a COM interface which combiness serial communication and signaling functions. With the help of optional UPS software, the serial interface allows a range of monitoring functions to be implemented.

FRIENDLY STATUS DISPLAY PANEL
All operation and olad conditions are indicated by the LCDs. The audible alarm also warns critical operational conditions for user to save the files you are currently working on.

Protecion
  • Power Failure
  • Lightning and surges
  • Voltage variations
  • Voltage and frequency fluctuations
  • Brownout and overvoltage correction
  • Improvement the power supply quality
  • FRIENDLY STATUS DISPLAY PANEL
    All operation and olad conditions are indicated by the LCDs. The audible alarm also warns critical operational conditions for user to save the files you are currently working on.
    Applications
  • Computer centers
  • Server applications
  • Networks and workstation
  • Bank automation systems
  • Telecommunication systems
  • Transport systems

  • TRUE ON-LINE DOUBLE CONVERSION TECHNOLOGY
    During mains power present, the UPS convers the mains AC voltage to DC to charge the battary and to supply the inverter with energy. The inverter generates a sinewave clean AC voltage at all times at the output of the UPS.
    The battery delivers the necessary power to the inverter if the mains power supplies failur. In case of overload or short circuit the S.T.S bypass systems guarantees the mains power automatically switch directly through to the output load.


    Specifications
    Model
    GEN-1060
    GEN-1100
    GEN-3100
    GEN-3150
    GEN-3200
    Power Rating
    6KVA
    10KVA
    10KVA
    15KVA
    20KVA
    Input
    Number of Phase
    Single Phase
    Three Phase
    Voltage
    120/220/230/240VAC+20%
    208/38/400/415VAC+20%
    Frequency
    50Hz / 60Hz ¡Ó5%
    Powe Factor
    >0.97
    >0.95
    Output
    Voltage
    SINGLE PHASE 120VAC/220VAC/230VAC/240VAC
    Frequency
    50Hz / 60Hz (auto synchronized with mains frequency)
    Static Voltage Regulation
    +/-2%
    Harmonic Distortion with linear load
    < 3%
    Overload Rating
    110%R.M.S For 10 seconds, 130%R.M.S For 1 second SHORT CIRCUIT PROOF
    Crest Ration
    3:1
    Efficiency
    90%
    Battery
    Type
    Maintenance free sealed lead-acid. 12V/7AH
    7AH
    11AH
    11AH
    17AH
    26AH
    Norinal Voltage
    240V
    Back-up time
    Full load
    6 min.
    6 min.
    6 min.
    8 min.
    10 min.
    Half load
    19 min.
    19 min.
    19 min.
    25 min.
    30 min.
    Transfer Time
    Uninterruptible transfer of 100% load from UPS to bypass & vice versa
    Indicator
    Load status, Battery Status, UPS Operation status
    Audible Alarm
    Power failure, Battery mode, Overload, UPS failure
    Interface
    DB-9 Port, RS-232
    Noise Level in dBA
    < 56
    Environment
    Temperature
    0°C to 40°C
    Humidity
    10% to 90% (non-condensing)
    Mechanlcal
    Weight / net (kgs)
    128kgs
    230kgs
    475kgs
    Dimension (W x D x H)(In)
    20x60x81cm
    34x64x98cm
    38x63x98cm