Datron Products Co., Ltd.
P.O.Box 56-48,Taipei,Taiwan
TEL: 886-2-25079686
FAX:886-2-25062811
Email: ups@datron.com.tw

















Protections
  • Protection against power failure.
  • Improvement the power supply quality.
  • Lightning and surge protection.
  • Prevent line noise with EMI/RFI filters.
  • Brownout and overvoltage correction.
  • Voltage variations.
  • Applications
  • Personal computers.
  • Workstations and networks.
  • Telecommunication systems.
  • Bank automation systems.
  • Security systems.
  • Transport systems.

  • Online Technology with STS Bypass
    The UPS provide a sinewave clean AC power at all times. The double conversion configuration keeps the inverter working constantly, ensuring that no interruption will occur in case of mains failure. The S.T.S. Bypass system guarantees the mains power automatically switched directly through to the output.


    Plug and Play
    The GEN UPS systems are ready for operation, just connect the UPS to the PC or network, plug it in and switch it on.
    Micro-Processor Control
    The traditional complex hardware circuitry is embedded in the most advanced microprocessor to reduce the failure rate and save space.
    PFC Technology
    Higher efficiency is attained using high input power factor correction technology together with the latest IGBT power factor components, in compliance with the latet energy-saving requirements of Europe.
    Auto-Sensing

    Upon power on, the UPS will start to perform a self-test on its components and the load, so as to detect problems immediately and prevent any errors.

    Self-protection Feature
    Equipped with the self-protection feature, the system shuts itself down upon of overloads, short-circuit, low battery voltage, or excessive temperature.
    RS-232 Serial Interface
    Used in conjunction with software operations, the RS-232 interface enables the UPS to be monitored directly through a computer monitor, to display the operation status on the PC monitor and simplify network management tasks..
    User friendly control panel
    All operational and load conditions are indicated by the LEDs or LCD. The audible alarm also warns critical operational conditions for user to save the data.


    Specifications
    Model
    GEN-1K
    GEN-1.5K
    GEN-2K
    GEN-3K
    Power Rating
    1000VA
    1500VA
    2000VA
    3000VA
    Input
    Nominal Voltage
    120VAC/220VAC
    Voltage Range
    160-300VAC
    60-138VAC
    Frequency
    50Hz or 60Hz+/-8%
    Powe Factor
    >0.95
    >0.97
    Output
    Voltage
    120VAC/220VAC+/-2%
    Frequency
    Synchronized (Line mode),50Hz or 60Hz +/- 0.5% (Batlery mode)
    Wave-form
    True Sine wave
    Distortion
    <3% (linear load)
    <4%(Full linear load)
    Capacity
    105%-150% for 30 sec., >150 % for 200ms
    Crest Ration
    3:1
    Battery
    Battery Voltage
    36V/3pcs
    48V/4pcs
    96V/8pcs
    96V/8pcs
    Type
    Maintenance free sealed lead-acid. 12V/7AH
    Back-up time
    Full load
    6 min.
    6 min.
    6 min.
    6 min.
    Half load
    17 min.
    17 min.
    17 min.
    17 min.
    On-Line Operation
    Zero break at input line loss and recovery
    Bypass
    Automatic
    Overload and UPS failure
    Transfer Time
    0 ms (2.Sms Inverter to bypass)
    Display Remoabe
    (LCD Series)
    UPS status, I/P & O/P Voltage & Frequency, Load %, Battery Voltage & %, Temperature, Model Spec., Event Log
    Normal (Green), Warning (Yellow), Fault (Red)
    Display
    (LED Series)
    Normal (Green), Bypass (Yellow), Battery Low (Yellow), Inverter (Green), Load% (5 LEDs)
    Battery % (5 LEDs), Fault (Red)
    Audible Alarm
    Battery Mode
    Beeping every 4 seconds(re-seltable) and per second when baltery low
    Overload
    Beeping twice per second
    Fault
    Beep Continuously
    Output
    Socket
    Tower
    NEMA 5-15R x 3pcs or
    IEC320 x 4pcs
    NEMA 5-15R x 3pcs or IEC320 x 3pcs + Terminal Block
    Rack(2U)
    NEMA 5-15R x 4pcs or
    IEC320 x 4pcs
    NEMA 5-15R x 2pcs or IEC320 x 3pcs + Terminal Block
    Interface
    UPSilon 2000 monitoring software
    For Net Agent II (Option) with SNMP manager and Web browser
    Networ
    RJ45 I/O port available for 10 base-T network or Fax/Modem
    Environment
    Temperature
    0-40 degree C; 32-104 degree F
    Humidity
    0-95% non-condensing
    Acoustic Noise
    Less than 45dBA (at1M)
    Less than50dBA(at1meter)
    Mechanlcal
    Weight / net (kgs)
    15
    20
    34
    35
    Dimension (W x D x H)(In)
    16x40x22
    15x47x22
    20x45x36
    20x35x36